UTL Solar Management Unit 40Amp -12V/24V

Type

Select Quantity

Manufacturer
UTL

Uganda Telecom Limited (UTL)

Founded

1989

Headquarter

India

Solartrade Partner
Product Description

High Speed with high Performance

UTL`s solar management unit (SMU) is embed with a high speed microcontroller which increases the performance of the solar system. Solar management unit provide ability to perform its task more reliably and efficiently.

High Reliability with Longer Operational Life

It is highly reliable and it has longer operational life. Solar management unit can be operated in extreme environment conditions and can be operated at temperature range that lies in 0°C to 60°C.

Prioritize Solar Power over Grid Power

SMU ensures priority usage of solar energy over government electricity (grid) to reduce grid consumption. In daytime condition, the system will give priority to solar energy and use grid power only when the solar power is insufficient to sustain the load requirement.

Increase the battery lifetime

SMU utilizes four stage battery charging algorithm that enhances the battery lifespan. In bulk stage SMU feeds the battery installed to it a constant boost charging current until its voltage reaches 14.4V and the float current, then in absorption stage it maintains this voltage above 14.2V for 3 hrs.

Automatic/ Manual Operation

The system can work as a domestic inverter and a solar inverter automatically or manually through a switch except in night condition. In night condition, first it will harvests the stored battery energy then it will work as normal domestic inverter.

Inbuilt Protection to Avoid Battery Undercharge and Over-charge

SMU has the capability to charge a solar battery which goes in deep discharge condition. It can charge the battery if the battery voltage during discharge reaches up to 8V per battery. Solar management unit uses four stages to charge the battery i.e. Boost, Absorption, Float and Equalization. This feature protects the battery for being over charged.

Very Low Consumption in Idle State

It have very low idle consumption, in idle state it consumes less than 20mA current which makes it more efficient than any other solar management unit.

Electronic protection

  • Over charging Voltage
  • Over charging Current
  • Under voltage
  • Battery reverse polarity protection
  • Solar reverse polarity protection
  • Reverse current flow at night from battery to solar array
  • Over temperature
  • Solar Low Voltage

Display Parameter

  • Battery - Voltage, Current, Type
  • Solar- Voltage, Current
  • Mode Selection
  • Solar Status – High, Low, Overload, Overheat.
  • Saving kWh
  • Mains Present – Low, High, Absent

Maximum PV Current

Special Features

There are some special features that given below.

  • High Speed and High Performance micro-controller
  • High reliability with longer operational life
  • Inbuilt protection to avoid battery undercharge and over-charge
  • Inbuilt PWM Technology Charge Controller
  • Automatic voltage selection for 12V or 24V
  • Solar Prioritization
  • Compact design with wall mounting
  • Eco friendly

General

Particulars

Description

SMU Capacity

SMU1224/40

Operating Temperature

0°C to 50°C

Storage Temperature

-20° C to 60°C

Battery Type

Tubular/SMF, Battery 12V/24V

Battery Capacity AH

100AH – 180AH

Battery charging regulation method

Bulk, Absorption, Float, Equalise

Electrical

Nominal System Voltage

12/24 DC

Charging Current (Solar)

20A-40A

Charge Controller Efficiency

>95%

Idle Consumption

<20mA

Operating Solar Input Voltage (VOC)

22.5V/45V

Max. Solar Input Voltage (VOC)

25A/45V

Min Solar Input Voltage (VOC)

15V/30V ± 2%

Solar Panel Recovery Voltage

17V/31V ± 2%

Max. Solar Current

40A

Efficiency

>95%

Battery Set Point @25 °C

Absorption voltage Tubular Battery

14.2V/28.4V±2%

Absorption voltage SMF Battery

13.7V/27.4V±2%

Absorption Duration

3hr

Float Voltage Tubular Battery

14V/28±2%

Float Voltage SMF Battery

13.7V/27.0V±2%

Bulk Voltage Tubular Battery

14.6V/29.2V±2%

Equalise Voltage

14.9/29.8V±2%

Equalise Duration

3hr

Equalise Calendar

28days

Mains reconnect when Solar not Present

At any Battery Voltage

Mains reconnect  when insufficient solar power

≤ 11.8V/23.6V ± 2%

Mains disconnect  when sufficient solar power for Tubular

≥ 13.8V/27.6V ± 2%

Mains disconnect when sufficient solar power for SMF

13.7V/27.4V ± 2%

Physical

Fixing

Wall Mounted

Weight

1.5Kg

Ingress Protection

IP-20

Dimension

9X6X3 inch

 

Related Products